Chapter 10 : RS-232 PROGRAMMER'S GUIDE SMART FADE™
PAGE 42
10-5. COMMANDS DESCRIPTION (continued)
NOTE d: Bit 1 of the Y command is dedicated to associating an Input (X or Y) to the beginning and ending position
of the Manual Fade’s Control Bar.
LCD DISPLAY OR OTHER SOFTWARE’S MANUAL FADE CONTROL BAR
BIT 1 of Y command VALUE of @ command
Command returning
the INPUT X
Command returning
the INPUT Y
0 0 i I
0 100 I i
1 0 I i
1 100 i I
• ?, K, R, L, X, commands are the status of the device’s internal firmware (read only).
10-6. ASCII / HEX / DEC TABLE
ASCII HEX DEC ASCII HEX DEC ASCII HEX DEC
space 20 32 @ 40 64 ` 60 96
! 21 33 A 41 65 a 61 97
" 22 34 B 42 66 b 62 98
# 23 35 C 43 67 c 63 99
$ 24 36 D 44 68 d 64 100
% 25 37 E 45 69 e 65 101
& 26 38 F 46 70 f 66 102
’ 27 39 G 47 71 g 67 103
( 28 40 H 48 72 h 68 104
) 29 41 I 49 73 i 69 105
* 2A 42 J 4A 74 j 6A 106
+ 2B 43 K 4B 75 k 6B 107
, 2C 44 L 4C 76 l 6C 108
- 2D 45 M 4D 77 m 6D 109
. 2E 46 N 4E 78 n 6E 110
/ 2 F 47 O 4 F 79 o 6 F 111
0 30 48 P 50 80 p 70 112
1 31 49 Q 51 81 q 71 113
2 32 50 R 52 82 r 72 114
3 33 51 S 53 83 s 73 115
4 34 52 T 54 84 t 74 116
5 35 53 U 55 85 u 75 117
6 36 54 V 56 86 v 76 118
7 37 55 W 57 87 w 77 119
8 38 56 X 58 88 x 78 120
9 39 57 Y 59 89 y 79 121
: 3A 58 Z 5A 90 z 7A 122
; 3B 59 [ 5B 91 { 7B 123
< 3C 60 \ 5C 92 | 7C 124
= 3D 61 ] 5D 93 } 7D 125
> 3E 62 ^ 5E 94
~
7E 126
? 3F 63
_
5F 95 DEL 7F 127
INPUT X INPUT Y
= 0
= 100
Comentários a estes Manuais