19
Group Name Cmd
Resp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
PE_SMOOTH_MOVE ps ps « Smooth Move » activation Rd/Wr 0 1 1 1 = Enable.
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2
PE_NEW_ID pN pN Unique layer identifier number Rd/Wr 0 1 0
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2
PE_POS_H pH pH
Layer left H position on output
screen
Rd/Wr 0 65535
32768
Unit = pixels ( 32768 = screen
left border )
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2