PAGE 19
Chapter 6 : UPDATING THE DEVICE
The OCTO-QUATTRO
can be updated thanks a COMPUTER (PC) via its RS-232 communication port only.
6-1. CONNECTIONS
c Connect the "RS-232" connector of the OCTO-QUATTRO
to the SERIAL port of your COMPUTER with a DB9
M/F straight cable.
d Connect the OCTO-QUATTRO
to an AC power outlet.
e Switch OFF the OCTO-QUATTRO
(FRONT PANEL SWITCH = O).
6-2. UPDATE INSTRUCTIONS
c Open the file: Octo-Range-Update.exe (in Start > Program > ANALOGWAY > Octo-Range).
d In the Port menu select the COM port connected to the device.
e Click on "START" on the SOFTWARE.
f Press the ENTER button of the OCTO-QUATTRO
(FRONT PANEL), and SWITCH it ON simultaneously
(FRONT PANEL SWITCH = I ). The LCD screen displays Downloading, and the upgrade will start. Then you can
release the ENTER button.
g When the software displays "Program operation completed", SWITCH OFF and ON the OCTO-QUATTRO
with
the FRONT PANEL SWITCH.
h Click on the "Quit" button to close the update SOFTWARE.
NOTE:
YOUR OCTO-QUATTRO
IS NOW READY TO WORK.
NOTE:
If the "BAD TYPE DEVICE" message appears, selects the devices type in the Device menu, and renew the
previous operations (e to h).