Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
STDBYPROJ_RATE
wR
wR
Output display device UART speed
Rd/Wr 0 3 2
0 = 1200bauds
1 = 2400bauds
2 = 9600bauds
3 = 19200bauds
STDBYPROJ_CTRL
wC
wC
Rd/Wr 0 4 0
0 = No request
1 = Wake up request
2 = Standby request
3 = Clear Wake up message
4 = Clear standby message
VERSION
VERI1 xi xi Byte 0 and 1 of the device ID Rd 0 65535
0 ex : AAAA
VERI2 xj xj Byte 2 and 3 of the device ID Rd 0 65535
0 ex : AAAA
VERI3 xk xk Byte 4 and 5 of the device ID Rd 0 65535
0 ex : AAAA
VERI4 xl xl Byte 6 and 7 of the device ID Rd 0 65535
0 ex : AAAA
VERK xK xK
Checksum/version of the
programmable components
Rd/Wr 0 65535
0
0 = Number of
programmables
components
1 = Main micro-
controler
2 = Front panel
micro-controler
3 = FPGA Caecina
4 = FPGA Fannia
5 = FPGA Thrasea
6 = Synchro CPLD
VERV xV xV Variable set version Rd 0 65535
42
VERUPD xU xU Updater version Rd 0 65535
0
OPT yo yo Detected options Rd 0 65535
0
bit 0 = Lan Module
bit 1 = SDI In 1 board (SDI 1
and 2)
bit 2 = Recording board
bit 3 = CF Caecina
bit 4 = CF Fannia
bit 5 = CF Thrasea
bit 6 = SDI In 2 board (SDI 3
and 4)
bit 7 = Audio Evolution
bit 8 = HDCP DVI In Evolution
REV xR xR Moher board revision Rd 0 255 0
INPUT IN_AUTOSET_ALL Ia Ia
Auto
-setting request for all the
inputs
Rd/Wr 0 1 0