Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
PE_CLOSING_DURATION cD cD Layer closing transition duration Rd/Wr 0 255 10 Unit = 1/10s
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory Preset
1
4 = Memory Preset
2
5 = Memory Preset
3
6 = Memory Preset
4
7 = Memory Preset
5
8 = Memory Preset
6
9 = Memory Preset
7
10 = Memory
Preset 8
0 = Background
Frame for output 1
1 = Background
Frame for output 2
in matrix mode
2 = Background
Layer for output 1
3 = Pip 1 Layer for
output1
Background Layer
for output 2 in
matrix mode
4 = Pip 2 Layer for
output1
5 = Pip 3 Layer for
output1 in
quadravision mode
Pip1 Layer for
output 2 in matrix
mode
6 = Logo 1
7 = Logo 2
8 = Audio Output 1
9 = Audio Output 2
PRESET
CONTROL
TAKE TK TK
TAKE, Next preset becomes
Current
Rd/Wr 0 1 0
TAKEAVA TA TA
Available TAKE flag
Rd 0 1 1
TAKEINFO TI TI TAKE information Rd 0 2 0
0 = 1 shot TAKE
1 = 2 shot TAKE
2 = Sequenced TAKE
TBAR NT NT TBAR value Rd/Wr 0 10000
0 Unit = 0,01%
COPY_FROM Nf Nf Source for preset copy Rd/Wr 0 10 0
0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4
7 = Memory Preset 5
8 = Memory Preset 6
9 = Memory Preset 7
10 = Memory Preset 8