HD SCAN™ Chapter 11 : RS-232 PROGRAMMER'S GUIDE (continued)
PAGE 21
11-4. COMMANDS AND RESPONSES TABLE
The following table resumes commands, which are recognized as valid, and the responses that will be returned to the
control device (on RS-232 port).
ASCII RESPONSE COMMAND TYPE VALUE
COMMAND DESCRIPTION MIN MAX DESCRIPTION
FRONT PANEL COMMANDS
z FRZ FREEZE. Rd/Wr 0 1 1 = image freeze.
a ASP Size mode selection. Rd/Wr 0 2 0 = 4/3.
1 = 16/9.
2 = ZOOM.
h HP Horizontal position adjustment. Rd/Wr 0 255
v VP Vertical position adjustment. Rd/Wr 0 255
w HW Horizontal size adjustment. Rd/Wr 0 255
s VS Vertical size adjustment. Rd/Wr 0 255
H ZHP Zoom horizontal position. Rd/Wr 0 255
V ZVP Zoom vertical position. Rd/Wr 0 255
W ZHW Zoom horizontal size. Rd/Wr 0 255 0 = 100% 255 =200%
S ZVS Zoom vertical size. Rd/Wr 0 255 0 = 100% 255 =200%
R REC RECALL. Rd/Wr 0 1 1 = recall (automatic reset)
M STO STORE. Rd/Wr 0 1 1 = store (automatic reset)
INPUT COMMANDS
GP REFP Genlock H phase adjustment Rd/Wr 0 65535
E SOGI SOG input selection. Rd/Wr 0 1 0 = no 1 = yes.
l LOAD H sync load selection. Rd/Wr 0 1 0 = Hi-Z 1 = 75 ohms.
OUTPUT COMMANDS
F OFMT Output format selection Rd/Wr 0 7 0 = 720p @ 59.94Hz 4 = 1080i @ 50Hz
1 = 720p @ 60Hz 5 = 1080i @ 59.94Hz
2 = 1035i @ 59.94Hz 6 = 1080i @ 60Hz.
3 = 1035i @ 60Hz
GR REFR Synchronization mode selection. Rd/Wr 0 2 0 = internal.
1 = genlock.
e OSYN Sync type selection. Rd/Wr 0 1 0 = tri-levels.
1 = bi-levels.
P OPAT Test pattern selection. Rd/Wr 0 1 0 = no test pattern.
1 = test pattern selected.
IMAGE COMMANDS
f FLK Flicker level selection. Rd/Wr 0 7
k BLK Black level adjustment Rd/Wr 0 255
r RLV Red level adjustment. Rd/Wr 0 127
g GLV Green level adjustment. Rd/Wr 0 127
b BLV Bleu level adjustment. Rd/Wr 0 127
o OVR Under/overscan mode selection. Rd/Wr 0 1 0 = underscan 1 = overscan
L HSMT Horizontal smooth Rd/Wr 0 1 0 = OFF 1 = ON.
yp PRES PRESET Rd/Wr 0 1 1 = PRESET (automatic reset).
CONTROLS COMMANDS
yl LOCK Front panel locking selection. Rd/Wr 0 1 0 = unlock 1 = lock.
yc EPOS Erase memory. Rd/Wr 0 1 1 = erase all memories (automatic reset).
Y FRES Default value. Rd/Wr 0 1 1 = set all the parameters to the default value
(automatic reset).
xk K_ K internal version Rd 0 65535
xs S_ S internal version Rd 0 65535
xf F_ F internal version Rd 0 65535
xi I_ Identification number. Rd 0 65535
yo OPT HD SCAN options. Rd 0 65535
Z IFRM Freeze mode Rd/Wr 0 1 0 = slow 1 = fast.
NOTE: Rd = Read only command. Rd/Wr = Read and write command.